OpenMS
2.4.0
|
Calculates masses and mass-to-charge ratios of peptide sequences.
Given a peptide sequence and a charge state, the charged mass (including H+ adducts) and the mass-to-charge ratio are computed. The peptide sequence can include modifications (for information on valid notation see the AASequence class documentation). Neutral masses can be computed by using "0" as charge state.
Input can be given directly as values of the parameters: in_seq
for peptide sequences and charge
for charge states. Alternatively, it can be read from a file (see parameter in
) with the following format: A peptide sequence at the beginning of each line, optionally followed by any number of charge states. Whitespace, commas or semicolons can de used to delimit the different items. Parts of the input that cannot be understood will be skipped. If charge states are given in the input file as well as via the charge
parameter, results are returned for the union of both sets of charge states.
Output can be written to a file or to the screen (see parameter out
). Results for different charge states are always ordered from lowest to highest charge. A number of different output formats are available via the parameter format:
list
writes a human-readable list of the form "ABCDEF: z=1 m=566.192 m/z=566.192, z=2 m=567.199 m/z=283.599";table
produces a CSV-like table (using parameter separator
to delimit fields) with the columns "peptide", "charge", "mass", and "mass-to-charge", and with one row per peptide and charge state;mass_only
writes only mass values (one line per peptide, values for different charge states separated by spaces);mz_only
writes only mass-to-charge ratios (one line per peptide, values for different charge states separated by spaces).The command line parameters of this tool are:
Residue::getResidueTypeName: residue type has no name Residue::getResidueTypeName: residue type has no name Residue::getResidueTypeName: residue type has no name Residue::getResidueTypeName: residue type has no name Residue::getResidueTypeName: residue type has no name Residue::getResidueTypeName: residue type has no name Residue::getResidueTypeName: residue type has no name MassCalculator -- Calculates masses and mass-to-charge ratios of peptide sequences Version: 2.4.0 Oct 29 2018, 15:52:19, Revision: 9690d06 To cite OpenMS: Rost HL, Sachsenberg T, Aiche S, Bielow C et al.. OpenMS: a flexible open-source software platform for mass spectrometry data analysis. Nat Meth. 2016; 13, 9: 741-748. doi:10.1038/nmeth.3959. Usage: MassCalculator <options> Options (mandatory options marked with '*'): -in <file> Input file with peptide sequences and optionally charge numbers (mutually excl usive to 'in_seq') (valid formats: 'txt') -in_seq <peptide_sequences> List of peptide sequences (mutually exclusive to 'in') -out <file> Output file; if empty, output is written to the screen (valid formats: 'txt') -charge <numbers> List of charge states; required if 'in_seq' is given (default: '[0]') -format <choice> Output format ('list': human-readable list, 'table': CSV-like table, 'mass_onl y': mass values only, 'mz_only': m/z values only) (default: 'list' valid: 'list', 'table', 'mass_only', 'mz_only') -average_mass Compute average (instead of monoisotopic) peptide masses -fragment_type <choice> For what type of sequence/fragment the mass should be computed (default: 'full' valid: 'full', 'internal', 'N-terminal', 'C-terminal', 'a-i on', 'b-ion', 'c-ion', 'x-ion', 'y-ion', 'z-ion') -separator <sep> Field separator for 'table' output format; by default, the 'tab' character is used Common UTIL options: -ini <file> Use the given TOPP INI file -threads <n> Sets the number of threads allowed to be used by the TOPP tool (default: '1') -write_ini <file> Writes the default configuration file --help Shows options --helphelp Shows all options (including advanced)
INI file documentation of this tool: