47 static const std::string NamesOfScanMode[SIZE_OF_SCANMODE];
Description of the settings a MS Instrument was run with.
Definition: InstrumentSettings.h:23
ScanMode getScanMode() const
returns the scan mode
void setPolarity(IonSource::Polarity polarity)
sets the polarity
IonSource::Polarity polarity_
Definition: InstrumentSettings.h:93
bool zoom_scan_
Definition: InstrumentSettings.h:92
InstrumentSettings & operator=(const InstrumentSettings &)=default
Assignment operator.
InstrumentSettings()
Constructor.
IonSource::Polarity getPolarity() const
returns the polarity
bool operator==(const InstrumentSettings &rhs) const
Equality operator.
std::vector< ScanWindow > & getScanWindows()
returns a mutable reference to the m/z scan windows
InstrumentSettings(InstrumentSettings &&)=default
Move constructor.
void setZoomScan(bool zoom_scan)
sets if this scan is a zoom (enhanced resolution) scan
std::vector< ScanWindow > scan_windows_
Definition: InstrumentSettings.h:94
bool operator!=(const InstrumentSettings &rhs) const
Equality operator.
InstrumentSettings & operator=(InstrumentSettings &&) &=default
Move assignment operator.
ScanMode scan_mode_
Definition: InstrumentSettings.h:91
void setScanWindows(std::vector< ScanWindow > scan_windows)
sets the m/z scan windows
~InstrumentSettings()
Destructor.
void setScanMode(ScanMode scan_mode)
sets the scan mode
InstrumentSettings(const InstrumentSettings &)=default
Copy constructor.
bool getZoomScan() const
return if this scan is a zoom (enhanced resolution) scan
const std::vector< ScanWindow > & getScanWindows() const
returns a const reference to the m/z scan windows
ScanMode
scan mode
Definition: InstrumentSettings.h:27
@ MASSSPECTRUM
general spectrum type
Definition: InstrumentSettings.h:29
@ SRM
Selected reaction monitoring scan Synonyms: 'Multiple reaction monitoring scan',...
Definition: InstrumentSettings.h:33
@ EMR
Electromagnetic radiation scan Synonyms: 'EMR spectrum'.
Definition: InstrumentSettings.h:40
@ TDF
Time-delayed fragmentation scan.
Definition: InstrumentSettings.h:39
@ EMISSION
Emission scan.
Definition: InstrumentSettings.h:41
@ UNKNOWN
Unknown scan method.
Definition: InstrumentSettings.h:28
@ PRECURSOR
Precursor ion scan.
Definition: InstrumentSettings.h:37
@ MS1SPECTRUM
full scan mass spectrum, is a "mass spectrum" Synonyms: 'full spectrum', 'Q1 spectrum',...
Definition: InstrumentSettings.h:30
@ CNG
Constant neutral gain scan Synonyms: 'CNG scan'.
Definition: InstrumentSettings.h:35
@ ABSORPTION
Absorption scan.
Definition: InstrumentSettings.h:42
@ EMC
Enhanced multiply charged scan.
Definition: InstrumentSettings.h:38
@ SIM
Selected ion monitoring scan Synonyms: 'Multiple ion monitoring scan', 'SIM scan',...
Definition: InstrumentSettings.h:32
@ MSNSPECTRUM
MS2+ mass spectrum, is a "mass spectrum".
Definition: InstrumentSettings.h:31
@ CRM
Consecutive reaction monitoring scan Synonyms: 'CRM scan'.
Definition: InstrumentSettings.h:34
@ CNL
Constant neutral loss scan Synonyms: 'CNG scan'.
Definition: InstrumentSettings.h:36
Polarity
Polarity of the ion source.
Definition: IonSource.h:115
Main OpenMS namespace.
Definition: FeatureDeconvolution.h:22